Categories

×
Home / Electrical & Electronics / Electrical Panel / Active Harmonic Filter
You Might Also Like :

SUBMERSIBLE PUMP

₹ ask me

Sintex LED Bulb

₹ 200 / Piece

Active Harmonic Filter

Wire Consultancy

₹ 2.5 Lakh / Piece

Feature : Wall mounted AHF
Feature : Touch LCD screen for online monitoring

Product Description :

In order to maximize our client satisfaction, we are engaged in offering a highly effective assortment of Active Harmonic Filterfor our valuable customers.

Features :
 

  • Wall mounted AHF
  • Easy to replace module
  • Touch LCD screen for online monitoring
  • Longer working life


Description:

Functions:

Reduce harmonics level (Below IEEE limits 5%)
Improve Power Factor (Above 0.99)
Balance load current

Products Range:

A pioneer in the past, a leader today in the industry most comprehensive capacity series of APF

400V AHF Products series: 25A 35A 50A 60A 100A 200A~600A
480V AHF Products series: 75A 150A 225A 300A
690V AHF Products series: 75A 150A 225A 300A
 

Coverage :
 

  • Compact in size
  • 18 Months product warranty
  • Wall mounted AHF
  • Easy to replace module
  • Touch LCD screen for online monitoring
  • No resonance and many more.

 

Active Harmonic Filter Data Sheet
System parameters
1 Voltage of rated AC input line 400V
2 Input frequency 45Hz 63Hz
3 Permitted parallel units No limit
4 efficiency ≥98/%
5 Network configuration Three phases and three lines, three phases and four lines
6 CT setting 150/5 10,000/5
AHF mechanical characteristics
1 Mechanical dimension W×D×H 440×470×150 mm
2 Weight 18 Kg
3 Gross Weight 20 Kg
4 Protection level IP20
AHF AC input (mains supply)
1 Rated voltage of input line 380/400/415
2 Scope of input phase voltage 132V264V
3 Frequency 50/60Hz (scope: 45Hz~63Hz)
4 Forced cooling 151 L/sec
5 Normal mode (full load) loss <0.52/0.73
6 Overall efficiency >97
Environmental characteristics
1 Noise (within 1 meter) 52DB
2 Altitude For <1,500m, or >1,500m, refer to GB/T3859.2derating
3 Relative Humidity 5%~95%, no condensation
4 Operating temperature -1040 Deg
5 AHF storage temperature 20-70 Deg
European and International standards
1 General safety requirements for AHF use and operation area EN 50178:1997/IEC 50178:1997
2 AHF EMC requirements EN 61000_6_2(2005)/ EN55011,GROUP1,CALSSA

 
AHF performance requirements EN 50091-3/IEC 62040-3/AS 62040-3(VFI SS 111)

Benefits:

  • Significantly reduced Voltage Waveform Distortion
  • Reduced Voltage Drops on Transformers and Cables
  • Reduced Temperature rise on Transformers and Cables
  • No risk of harmonic Resonance / Improved Power Factor
Product Specification :
Feature : Wall mounted AHF
Feature : Touch LCD screen for online monitoring
Wire Consultancy

Address : GF, F-70, West Vinod Nagar
Email : :info@wireconsultants.com